Skip to main content

EcoSystem 50 Smoke & Heat Evacuation

Technical information

Performance

Energy

Thermal insulation - Uf
2.3 W/m²K
Thermal insulation - Uw
1.4 W/m²K
Uw Dependencies
Frame-vent HI+: Ug 1.0W/m²K, warm edge spacer,@1.23x1.48m (86mm sight line), 24mm glass

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class 9A (600Pa)
Wind load resistance
Class C3 (1200Pa)
Opening & closing resistance
Class 2
Performances and properties depend on size, profile combinations, hardware and infill choices. Please contact your Reynaers Aluminium representative.

Properties

Max. dimensions & weight

Min. height of vent
700 mm
Max. height of vent
2200 mm
Min. width of vent
500 mm
Max. width of vent
1600 mm

Sightlines

Min. frame-vent width (inward opening)
92 mm
Min. vent-vent width (inward opening)
134 mm
Min. frame width (outward opening)
21 mm
Min. vent width (outward opening)
73 mm
Min. width T-profile
70 mm
Depth frame
50 mm
Depth Vent
59 mm
Depth frame-vent
59 mm

Glazing

Rebate height
22 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - External glazing - Glazing bead
Min. glass thickness - frame/element
12 mm
Max. glass thickness - frame/element
32 mm
Min. glass thickness - vent
4 mm
Max. glass thickness - vent
32 mm